CLOSED PHASE-CYCLE TECHNOLOGY
Water desalination and purification by freeze separation
Using R290 (propane) or CO₂ as the refrigerant. A complete Carnot cycle in a single reactor: physics instead of chemistry.
CLOSED PHASE-CYCLE TECHNOLOGY
Using R290 (propane) or CO₂ as the refrigerant. A complete Carnot cycle in a single reactor: physics instead of chemistry.
≈1.1 kWh/m³
Specific energy consumption
2–3×
Lower than the best global alternatives
0
Chemical reagents. Zero Chemistry
300 g/L
Brine concentration (RO: max 80 g/L)
EXISTING PROBLEM
The need for fresh water is well known, and at present the leading technology in the field of water desalination and recycling is reverse osmosis in its various forms. The efforts of numerous scientists and engineers continue to improve RO systems, but overall the technology has nearly reached the limit of its efficiency.
It seems that a new solution must be found.
KEY INNOVATION
Our proposal is to rethink the previously known freeze-based purification and desalination technology. A number of factors have naturally hindered its development in its traditional form: low productivity, high energy consumption, complex technological processes for washing ice and separation. But perhaps everything can be done differently.
Two phase transitions of water (ice formation and melting), as well as two phase transitions of R290 (evaporation and condensation), occur in a single reactor at different levels under gradually increasing pressure created by the temperature gradient between the lower and upper parts of the reactor.
HOW IT WORKS
01
7–10 meters high, filled with water under a pressure of about 6 bar.
02
In the lower part, liquid R290 is injected into warm seawater or water to be purified, where it immediately evaporates. Heat exchange between the gas and the water causes the formation of fine ice crystals, while the combination of pressure and temperature is not favorable for clathrate formation.
03
Gaseous propane and ice rise upward due to their lower density, with the use of a flow retardation mechanism, while the denser brine settles at the bottom. During the upward movement through the desalinated water layer, and partly due to flow turbulence, the ice fraction is washed.
04
Propane bubbles enter the low-temperature zone and, due to direct heat exchange, condense, releasing heat that causes the ice in the upper part of the reactor to melt. Energy circulates inside the system. About 96% of R290 condenses.
05
Liquid propane collects in the upper part of the reactor, fresh water is located beneath it, the injection zone holds a layer of seawater, heavy brine settles at the bottom. Uncondensed propane is periodically vented and returned to the cycle.
06
Phase 1: injection of R290, heat exchange, ice formation, gas condensation and ice melting. Phase 2: pumping liquid R290 and fresh water into a separator, pumping out brine and removing gaseous R290. Phase 3: filling the reactor with a new portion of seawater.
A Seawater intake B Separators C Heat exchangers and recuperators D R290 storage tank 01–06 Process steps above
In the separator, liquid propane and fresh water are divided into fractions and cyclically displaced by a pump to the R290 storage tank and to the fresh water recuperator. The remaining equipment (recuperators, heat exchangers, tanks, pumps, compressor) ensures operation of the plant.
THREE LEVELS OF ADVANTAGES
__________________________________
01
Specific energy consumption: about 1.1 kWh/m³. This is 2–3 times lower than that of the best global alternatives.
— Closed R290 cycle: minimal compression energy
— Recovery of pressure and cold from the product streams
__________________________________
02
Operation with any salinity: from seawater to supersaturated brines, where RO becomes inefficient.
— Zero Chemistry: complete absence of chemical reagents
— Closed R290 cycle: no gas emissions
— High reliability: no membranes subject to failure
— About 90% of the equipment is already mass-produced
— Onshore installation or a floating platform
__________________________________
03
The technology is designed to operate under artificial intelligence control, optimizing parameters in real time for maximum efficiency.
— Remote operation
— Ideal for islands, platforms and other isolated locations
SIGNIFICANT ADDITION
Unlike reverse osmosis technology (maximum 80 grams/liter), the technology of our concept makes it possible to form brine at a level of 300 grams/liter. This provides an opportunity to obtain, in addition to fresh water, significant quantities of NaCl, KCl, MgCl, as well as other basic materials.
________________________
300 g/L
Brine concentration (RO: maximum 80 g/L)
________________________
32 kg
High-quality technical-grade NaCl from 1 m³ of seawater (Red Sea conditions)
________________________
≈ USD 2
Project economics improvement per 1 m³, based on NaCl alone
________________________
85 / 15 %
Target ratio of desalinated water to brine
The brine from the lower part of the reactor is periodically pumped out at a base pressure of 6–7 bar and replaced with a new batch of seawater. In the salt tower a spray nozzle forms a fine brine mist; as water evaporates, solid salt particles fall into the tower collector. After centrifugation, high-quality technical-grade NaCl and mother liquor containing KCl, MgCl and other constituents, including boron and lithium, are obtained.
Taking into account the key concept of IDRA (idrawater.org), we aim to operate in a mode as close as possible to full recycling, which eliminates any discharge of brine into the sea. The evaporated water from the brine is routed to the fresh water storage tank; the mother liquor can be further processed or supplied to a specialized enterprise.
WATER RECYCLING
With certain equipment adjustments, the technology can be applied for high-quality water recycling in the chemical industry, non-ferrous metallurgy, oil and gas, power engineering, and other sectors. Equipment selection depends on the composition and temperature of the wastewater.
WHO IS OUR CUSTOMER?
__________________________________
Metallurgy, oil and gas, and chemical plants requiring water supply and brine disposal solutions.
__________________________________
Coastal cities and regions facing freshwater shortages.
__________________________________
Islands, resorts, offshore platforms, military bases.
Safety by design
Placing the propane storage tank underwater minimizes the risk of forming a gas-air mixture, and the amount of gaseous R290 simultaneously present in the system is minimal. If necessary, R290 can be replaced with CO₂, which drastically reduces the explosion hazard, at the cost of higher capital investment.
SHORT-TERM GOALS
We are interested in cooperation with relevant specialized organizations in order to:
01 Develop a comprehensive theoretical foundation for the process
02 Define the basic theoretically optimal operating modes for water desalination and purification
03 Design and manufacture a pilot unit, followed by a testing cycle, to bring the technology to TRL 6–7
ICEdesal
Freeze desalination based on
closed phase-cycle technology
© 2026 ICEdesal
CONTACT
DDHWays, Centro de Negócios de Ansião
Parque Empresarial do Camporês
3240-465 Chão de Couce, Portugal